Research > Microbe > Bacteria > MRSA
Common Generic Names
- Electrolytically Generated Hypochlorous Acid (HOCl)
- Neutral Electrolyzed Water (NEW)
- Electrolyzed Oxidizing Water (EOW)
- Electro-chemically Activated Water (ECA)
- Super-oxidized water (SOW)
Results: 4 published articles
Microbe(s): Methicillin-resistant Staphylococcus aureus, MRSA
OBJECTIVE: Biofilms represent a key challenge in the treatment of chronic wounds, as they are among the main reasons for delays in chronic wound healing. This in vitro study was aimed at evaluating the activity of a new acid-oxidizing solution (AOS) on biofilm formation. Acid-oxidizing solution contains free chlorine species with stabilized hypochlorous acid in high concentration (> 95) and is RP2). Different approaches were used to assess the prevention and eradication of methicillin-resistant Staphyloccocus aureus biofilm by the study products. Xylitol and chlorhexidine were used as positive controls. The activity of the study products on the biofilm structure was evaluated analyzing the ultrastructural modification by scanning electron microscopy, while skin compatibility was assessed on noncolonized tissues measuring the metabolic activity of the cells. RESULTS: In all experiments, AOS showed to be active on the biofilm matrix, modifying its structure and allowing bacterial release from the matrix. In all experiments, no cytotoxicity was observed in the tissues treated with the product suggesting a good compatibility of AOS with skin tissues. Reference product 1 affected the biofilm, suggesting a disruption effect RP2 was slightly less active than AOS in modifying the biofilm structure. CONCLUSION: Treatment with AOS affects biofilm by modifying its structure and therefore facilitating local bacteria accessibility to bactericidal agents, with consequent potential clinical benefits in the treatment of chronic wounds.
An nvestigation into the in-vitro effectiveness of electrolyzed water against various microorganisms
Microbe(s): Acinetobacter baumannii, Escherichia coli, Enterococcus faecalis, Klebsiella pneumoniae, Pseudomonas aeruginosa, Staphylococcus aureus, Bacillus subtilis, Myroides spp, MRSA, VRE
The aim of this study was to investigate the in-vitro antimicrobial activity of usage and normal concentrations of electrolyzed water in hospital. In our study, the effects of different concentrations of electrolyzed water on two gram positive, four gram negative standard strains and clinical isolates of four gram negative, two gram positive, one spore-forming bacillus and Myroides spp strains that lead to hospital infections were researched. The effects of different concentrations and different contact times of Envirolyte electrolyzed water on cited strains were researched through method of qualitative suspension tests. Petri dishes fo bacteria have been incubated at 37 C 48 hours. Bactericidal disinfectant was interpreted to be effective at the end of the period due to the lack of growth. Solutions to which disinfectant were not added were prepared with an eye to control reproduction and controlcultures were made by using neutralizing agents. 1/1, 1/2, and 1/10 concentrations of Envirolyte electrolyzed water were found to be effective on the bacteria that lead to hospital infections used during all test times. As a conclusion, based upon the results we acquired, it was observed that Envirolyte electrolyzed water of 100 concentration would be convenient to be used for disinfection when diluted to a usage concentration of 1/10.
Microbe(s): Total Microbial Count, methicillin-susceptible Staphylococcus aureus (MSSA), methicillin-resistant Staphylococcus aureus (MRSA)
This study aimed to monitor the microbiological effect of cleaning near-patient sites over a 48-hour period with a novel disinfectant, electrolyzed water. One ward dedicated to acute care of the elderly population in a district general hospital in Scotland. Lockers, left and right cotsides, and overbed tables in 30 bed spaces were screened for aerobic colony count (ACC), methicillin-susceptible Staphylococcus aureus (MSSA), and methicillin-resistant S. aureus (MRSA) before cleaning with electrolyzed water. Sites were rescreened at varying intervals from 1 to 48 hours after cleaning. Microbial growth was quantified as colony-forming units (CFUs) per square centimeter and presence or absence of MSSA and MRSA at each site. The study was repeated 3 times at monthly intervals. There was an early and significant reduction in average ACC (360 sampled sites) from a before-cleaning level of 4.3 to 1.65 CFU/cm2 at 1 hour after disinfectant cleaning (P <.0001). Average counts then increased to 3.53 CFU/cm2 at 24 hours and 3.68 CFU/cm2 at 48 hours. Total MSSA/MRSA (34 isolates) decreased by 71% at 4 hours after cleaning but then increased to 155% (53 isolates) of precleaning levels at 24 hours. Cleaning with electrolyzed water reduced ACC and staphylococci on surfaces beside patients. ACC remained below precleaning levels at 48 hours, but MSSA/MRSA counts exceeded original levels at 24 hours after cleaning. Although disinfectant cleaning quickly reduces bioburden, additional investigation is required to clarify the reasons for rebound contamination of pathogens at near-patient sites.
Microbe(s): Bacillus spores, Candida, Acinetobacter, Shigella, Serratia, Proteus, Pseudomonas, Mycobacterium tuberculosis, Mycobacterium avium, Mycobacterium abscessus, MRSA, VRSE
Background : Disinfection is essential for the prevention of hospital infection. Medilox, an super oxidized water generated by Medilox (SOO SAN EC CO., LTD. Yongin, Korea) was developed as a disinfectant in Korea. This is not costly and does not caany clinical problems and environmental pollution. We evaluated bactericidal activity ofMedilox against several clinical isolates and standard strains. Method : Clinical isolates and reference ATCC strains were exposed to Medilox, an super oxidized water (80 ppm ofHOCl) generated by Medilox (SOO SAN ECCO., LTD. Yongin, Korea) for the various periods (0.5, 1, 2, 5, and 10 minutes). After the exposure mixture of microorganisms and Medilox solution was inoculated into tryptic soy broth and onto tryptic soy agar, Sabouraud dextrose agar or Ogawa medium and cultured at 35C. Results: All strains of bacteria, yeasts, mycobacteria and vegetative form of Bacillus subtilis were killed within 30 seconds after an exposure to Medilox (80 ppm ofHOCl) under clean and dirty conditions. But, spore form of Bacillus subtilis was killed within 5 minutes. Conclusion: It may be recommended that Medilox can be used for the effective disinfectant for hospital environments and high-level disinfectant for hospital infection control.