Research > Microbe > Bacteria > Campylobacter


Common Generic Names
  • Electrolytically Generated Hypochlorous Acid (HOCl)
  • Neutral Electrolyzed Water (NEW)
  • Electrolyzed Oxidizing Water (EOW)
  • Electro-chemically Activated Water (ECA)
  • Super-oxidized water (SOW)

Results: 8 published articles


Journal Cover

Microbe(s): Escherichia coli O104:H4, Listeria monocytogenes, Aeromonas hydrophila, Vibrio parahaemolyticus, Campylobacter jejuni


The effect of acidic electrolyzed water (AEW) on inactivating Escherichia coli O104:H4, Listeria monocytogenes, Aeromonas hyrol possible unhygienic practices during production and processing of shellfish without apparent changes in the quality of the shellfish.


Journal Cover

Microbe(s): Campylobacter


This study investigated the effectiveness of spraying electrolysed water for reducing the numbers of Campylobacter on chicken carcasses. Previous studies have used solutions with free chlorine concentrations above 25 ppm and low pH to treat inoculated carcasses. The four trials described here were carried out at process plants treating naturally contaminated, hot, birds with electrolysed sodium chloride or sodium carbonate solutions, plain water, or no water. The birds were chilled after treatment. Free chlorine concentrations were all below 20 ppm, pH was 7 units or more, and redox potentials were below 830 mV. None of the treatments produced more than a 0.3-log reduction in Campylobacter numbers compared to counts on untreated carcasses. This study concludes that, at the low chlorine concentrations allowed in the EU, spraying with electrolysed water is not an effective method of reducing the number or prevalence of Campylobacter on chicken carcasses.


Journal Cover

Microbe(s): Escherichia coli O104: H4, Listeria monocytogenes, Campylobacter jejuni, Aeromonas hydrophila, Vibrio parahaemolyticus


This study investigated the effect of electrolyzed water on pathogenic bacteria cell suspensions. Specifically, we evaluated the efficacy of strong and weak acidic electrolyzed waters (SACEW, WACEW) and strong and weak alkaline electrolyzed waters (SALEW, WALEW) on Vibrio parahaemolyticus, Listeria monocytogenes, Aeromonas hyificantly more resistant to ALEW compared to ACEW. Results also show that the bactericidal activity of SACEW (20 mg/mL ACC) was more effective than WACEW (10 mg/mL ACC) in terms of inactivating E. coli O104:H4. Alkaline-electrolyzed waters were found to reduce cell numbers by 13 log (P < 0.05). However, alkaline electrolyzed water was less effective (P < 0.05) than acidic electrolyzed treatment.


Journal Cover

Microbe(s): Escherichia coli, Campylobacter, Salmonella


A study was conducted to investigate the effects of spray washing broiler carcasses with acidified electrolyzed oxidizing water (EO) or sodium hypochlorite (HOCl) solutions for 5, 10, or 15 s. Commercial broiler carcasses were contaminated with 0.1 g of broiler cecal contents inoculated with 105 cells of Campylobacter and 105 cells of nalidixic acid-resistant Salmonella. Numbers of bacteria recovered from unwashed control carcasses were 6.7, 5.9, 6.3, and 3.9 log10 cfu/mL for total aerobic bacteria, Escherichia coli, Campylobacter, and Salmonella, respectively. Washing in either EO (50 mg/L of sodium hypochlorite, pH 2.4, oxidation reduction potential of 1,180 mV) or HOCl (50 mg/L of sodium hypochlorite, pH 8.0) significantly reduced the levels of bacteria recovered from carcasses (P < 0.05). Carcasses washed with EO had slightly lower levels of total aerobic bacteria (0.3 log10 cfu/mL) and E. coli (0.2 log10 cfu/mL) than HOCl-treated carcasses; however, populations of Campylobacter and Salmonella were comparable after washing in either solution. Increasing the carcass washing time from 5 to 10 s lowered the levels of total aerobic bacteria (6.1 vs. 5.8 log10 cfu/mL), E. coli (4.6 vs. 4.1 log10 cfu/mL), Campylobacter (5.2 vs. 4.2 log10 cfu/mL), and Salmonella (2.0 vs. 1.2 log10 cfu/mL), but no further microbiological reductions occurred when washing time was extended from 10 to 15 s. Data from the present study show that washing poultry carcasses with EO is slightly better (total aerobic bacteria and E. coli) or equivalent to (Campylobacter and Salmonella) washing with HOCl. Washing broiler carcasses for a period equivalent to 2 inside-outside bird washers (10 s) provided greater reductions in carcass bacterial populations than periods simulating 1 (5 s) or 3 inside-outside bird washers (15 s).


Journal Cover

Microbe(s): Campylobacter jejuni


This study was undertaken to investigate the efficacy of alkaline and acidic electrolyzed (EO) water in preventing and removing fecal contaminants and killing Campylobacter jejuni on poultry carcasses under simulated industrial processing conditions. New York dressed and defeathered chicken carcasses spot-inoculated with cecal material or C. jejuni were subjected to spraying treatment with alkaline EO or 10% trisodium phosphate (TSP) water or combinations of spraying and immersion treatments with acidic EO and chlorinated water, respectively. Prespraying chicken carcasses with alkaline EO water significantly lowered cecal material attachment scores (3.77) than tap water (4.07) and 10% TSP (4.08) upon treatment of the dorsal area. Combinations of pre- and postspraying were significantly more effective than postspraying only, especially when using alkaline EO water in removing fecal materials on the surface of chicken carcasses. Although treatment by immersion only in EO and chlorinated water significantly reduced the initial population (4.92 log10 cfu/g) of C. jejuni by 2.33 and 2.05 log10 cfu/g, respectively, combinations of spraying and immersion treatment did not improve the bactericidal effect of sanitizers. The results indicated that alkaline EO water might provide an alternative to TSP in preventing attachment and removal of feces on the surface of chicken carcasses. The results also suggested that chicken carcasses containing pathogenic microorganisms may contribute to the cross-contamination of whole batches of chickens during processing in the chiller tank and afterward.


Journal Cover

Microbe(s): Salmonella, Listeria, Campylobacter, Escherichia coli


In 1999 the foodborne pathogens Salmonella, Listeria, Campylobacter, and Escherichia coli (both O157 and non-O157) were estimated to cause more than 6 million illnesses and approximately 9000 deaths each year. However, the most recent Centers for Disease Control and Prevention report on the sources and incidence of foodborne disease, released in 2004, has shown a dramatic decrease in E. coli O157:H7 infections. Since raw beef products are the most frequently foodborne sources of these pathogens, the results of this report demonstrate that the microbiological quality of raw beef has improved greatly. During the intervening years, post-harvest interventions have continually improved, with new attention to hide decontamination and innovative treatments of carcasses. In addition, a system to hold and test beef trim or ground beef for E. coli O157:H7 before its release into commerce has provided an even greater level of safety. In this paper, we review the latest information on the prevalence of E. coli O157:H7 and other pathogens on beef, the evidence identifying the hide as the primary source of pathogens on beef carcasses, the efficacy of various hide and carcass interventions, and other developments that have led or have the potential to lead to even greater improvements in the microbial quality of beef.


Journal Cover

Microbe(s): Listeria monocytogenes, Salmonella typhimurium, Campylobacter coli


To date, the effectiveness of electrolyzed oxidizing (EO) water against bacteria associated with fresh pork has not been determined. Using a hand-held, food-grade garden sprayer, distilled water (W), chlorinated water (CL; 25 ppm), 2% lactic acid (LA), acidic EO water (EOA), or aged acidic EO water (AEOA; stored at 4 C for 24 h) was sprayed (15 s) onto pork bellies inoculated with feces containing Listeria monocytogenes (LM), Salmonella typhimurium (ST), and Campylobacter coli (CC). Remaining bacterial populations were determined immediately following treatment, after 2 days of aerobic storage, and again after 5 days of vacuum-packaged, refrigerated storage (day 7). While LA and EOA significantly reduced (p<0.05) populations of CC at days 0 and 7, there was no significant difference (p>0.05) between antimicrobial treatments when applied to pork inoculated with ST or LM. This study demonstrates that a 15-s spray with EOA has the ability to reduce CC associated with fresh pork surfaces. However, longer contact times may be necessary to reduce other microbial contaminants.


Journal Cover

Microbe(s): Campylobacter jejuni


The effectiveness of electrolyzed (EO) water for killing Campylobacter jejuni on poultry was evaluated. Complete inactivation of C. jejuni in pure culture occurred within 10 s after exposure to EO or chlorinated water, both of which contained 50 mg/l of residual chlorine. A strong bactericidal activity was also observed on the diluted EO water (containing 25 mg/l of residual chlorine) and the mean population of C. jejuni was reduced to less than 10 CFU/ml (detected only by enrichment for 48 h) after 10-s treatment. The diluted chlorine water (25 mg/l residual chlorine) was less effective than the diluted EO water for inactivation of C. jejuni. EO water was further evaluated for its effectiveness in reducing C. jejuni on chicken during washing. EO water treatment was equally effective as chlorinated water and both achieved reduction of C. jejuni by about 3 log10 CFU/g on chicken, whereas deionized water (control) treatment resulted in only 1 log10 CFU/g reduction. No viable cells of C. jejuni were recovered in EO and chlorinated water after washing treatment, whereas high populations of C. jejuni (4 log10 CFU/ml) were recovered in the wash solution after the control treatment. Our study demonstrated that EO water was very effective not only in reducing the populations of C. jejuni on chicken, but also could prevent cross-contamination of processing environments.